E-mail us

media@mtglobalindo.com

Best Choice Solutions

FHO5000 | GRANDWAY


FHO5000 series Optical Time Domain Reflectometer (OTDR) is an intelligent meter of a new generation for the detection of fiber communications systems. With the popularization of optical network construction in cities and countrysides, the measurement of optical network becomes short and disperse; FHO5000 is specially designed for that kind of application. It’s economic, having outstanding performance.

FHO5000 is manufactured with patience and carefulness, following the national standards to combine the rich experience and modern technology, subject to stringent mechanical, electronic and optical testing and quality assurance; in the other way, the new design makes FHO5000 more smart and compact and multi-purpose.
Whether you want to detect link layer in the construction and installation of optical network or proceed efficient maintenance and trouble shooting, FHO5000 can be your best assistant.

Structure


Humanized Test Interface

Quick fit in short time

 
 


 
 



Result transfer

Link in line

  1. Download reference traces and settings from database
  2. Send measurement results via email
  3. Ask for remote help
  4.  


Data Manager

 
 

High Compatibility

  1. Support:

    -Windows Vista (32/64 bit system)
    -Windows 7 (32/64 bit system)
    -Windows 8 (32/64 bit system)
    -Microsoft Office Excel 2007
    -Microsoft Office Excel 2010

 
 

  1.  
  2. Delicate Report
 
 


Specification
 
General

Dimension 253×168×73.6mm
1.5kg (battery included)
Display7 inch TFT-LCD with LED backlight (touch screen function is optional)
Interface1×RJ45 port, 3×USB port (USB 2.0, Type A USB×2, Type B USB×1)
Power Supply10V(dc), 100V(ac) to 240V(ac), 50~60Hz
Battery7.4V(dc)/4.4Ah lithium battery (with air traffic certification)
Operating time: 12 hours①, Telcordia GR-196-CORE
Charging time: <4 hours (power off)
Power SavingBacklight off: Disable/1 to 99 minutes
Auto shutdown: Disable/1 to 99 minutes
Data StorageInternal memory: 4GB (about 40,000 groups of curves)
LanguageUser selectable (English, Simplified Chinese, traditional Chinese, French, Korean, Russian, Spanish and Portuguese-contact us for availability of others)
Environmental ConditionsOperating temperature and humidity: -10℃~+50℃, ≤95% (non-condensation)
Storage temperature and humidity: -20℃~+75℃, ≤95% (non-condensation)
Proof: IP65 (IEC60529)
Accessories

Standard: Main unit, power adapter, Lithium battery, FC adapter, USB cord, User guide, CD disk, carrying case
Optional: SC/ST/LC adapter, Bare fiber adapter

Type②Testing Wavelength 
(MM: ±20nm, SM: ±10nm)
Dynamic Range (dB)③Event/Attenuation Dead-zone (m)④
FHO5000-M21850/130019/210.8/4
FHO5000-MD21850/1300
1310/1550
19/21
35/33
0.8/4
1/4
FHO5000-MD22850/1300
1310/1550
19/21
40/38
0.8/4
1/4
FHO5000-D261310/155026/240.8/4
FHO5000-D321310/155032/300.8/4
FHO5000-D351310/155035/330.8/4
FHO5000-D401310/155040/381/4
FHO5000-D431310/155043/411/5
FHO5000-D451310/155045/431/5
FHO5000-T40F1310/1550/162540/38/381/4
FHO5000-T43F1310/1550/162543/41/411/5
FHO5000-T45F1310/1550/162545/43/431/5
FHO5000-TC35F1310/1550/165035/33/310.8/4
FHO5000-TP351310/1490/155035/33/330.8/4
Pulse WidthSingle mode: 3ns, 5ns, 10ns, 20ns, 50ns, 100ns, 200ns, 500ns, 1μs, 2μs, 5μs, 10μs, 20μs
Multi-mode: 3ns, 5ns, 10ns, 20ns, 50ns, 100ns, 200ns, 500ns, 1μs, 2μs
Testing DistanceSingle mode: 100m, 500m, 2km, 5km, 10km, 20km, 40km, 80km, 120km, 160km, 240km
Multi-mode: 500m, 2km, 5km, 10km, 20km, 40km
Sampling Resolution Minimum 5cm
Sampling PointMaximum 128,000 points
Linearity ≤0.05dB/dB
scale IndicationX axis: 4m~70m/div, Y axis: Minimum 0.09dB/div
Distance Resolution0.01m
Distance Accuracy ±(1m+measuring distance×3×10-5+sampling resolution) (excluding IOR uncertainty)
Reflectance AccuracySingle mode: ±2dB, multi-mode: ±4dB
IOR Setting1.4000~1.7000, 0.0001 step
UnitsKm, miles, feet
OTDR Trace FormatTelcordia universal, SOR, issue 2 (SR-4731)
OTDR: User selectable automatic or manual set-up
Testing ModesVisual fault locator: Visible red light for fiber identification and troubleshooting
Light source: Stabilized Light Source (CW, 270Hz, 1kHz, 2kHz output)
Field microscope probe
Fiber Event Analysis-Reflective and non-reflective events: 0.01 to 1.99dB (0.01dB steps)
-Reflective: 0.01 to 32dB (0.01dB steps)
-Fiber end/break: 3 to 20dB (1dB steps)
Other Functions

Real time sweep: 1Hz
Averaging modes: Timed (1 to 3600 sec.)
Live Fiber detect: Verifies presence communication light in optical fiber
Trace overlay and comparison

VFL Module (Visual Fault Locator, as standard function):

Wavelength (±20nm)650nm
Power 10mw,CLASSIII B
Range12km
ConnectorFC/UPC
Launching Mode

CW/2Hz

OPM Module (Power Meter, as optional function):

Wavelength Range (±20nm)800~1700nm
Calibrated Wavelength850/1300/1310/1490/1550/1625/1650nm
Test RangeType A: -65~+5dBm (standard); Type B: -40~+23dBm (optional)
Resolution0.01dB
Accuracy±0.35dB±1nW
Modulation Identification270/1k/2kHz,Pinput≥-40dBm
Connector

FC/UPC

LS Module (Laser Source, as optional function):

Working Wavelength (±20nm)1310/1550/1625nm⑤
Output Power Adjustable -25~0dBm
Accuracy±0.5dB
Connector

FC/UPC

FM Module (Fiber Microscope, as optional function):

Magnification400X
Resolution1.0µm
View of Field0.40×0.31mm
Storage/working Condition-18℃~35℃
Dimension235×95×30mm
Sensor1/3 inch 2 million of pixel
Weight150g
USB1.1/2.0
Adapter⑥
 
SC-PC-F (For SC/PC adapter)
FC-PC-F (For FC/PC adapter)
LC-PC-F (For LC/PC adapter)
2.5PC-M (For 2.5mm connector, SC/PC, FC/PC, ST/PC)

Notes:


⑤1310/1550nm laser source uses OTDR1 port, and 1625nm or 850/1300nm uses OTDR2 port.
⑥For more adapters, please contact us.



Ordering Information
 